Advertisement
Scientific Article| Volume 47, ISSUE 9, P899.e1-899.e6, September 2022

Blocking Plate for Volar Proximal Interphalangeal Joint Fracture Dislocation

Published:September 17, 2021DOI:https://doi.org/10.1016/j.jhsa.2021.07.025

      Purpose

      To assess the use of a 2-mm miniplate as a dorsal blocking plate to stabilize the central avulsion fragment in a proximal interphalangeal joint (PIP) volar fracture dislocation.

      Methods

      This was a case series comprising 8 patients with volar fracture dislocation of the PIP joint. The average age of the patients was 36 years. The patients were managed by this technique within an average of 11 days following the injury. The clinical outcome measurements included the assessment of pain and range of motion of the PIP and distal interphalangeal joints.

      Results

      The average follow-up duration was 20 months. The mean visual analog scale pain score was 1.9. The average range of motion of the PIP joint was 82°, whereas the average range of motion of the distal interphalangeal joint was 43°. Reduction of the subluxation was achieved in all cases, with no articular step remaining.

      Conclusions

      A dorsal blocking plate is a simple technique, associated with a satisfactory outcome, for volar fracture dislocation injuries of the PIP joint.

      Type of study/level of evidence

      Therapeutic V.

      Key words

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Journal of Hand Surgery
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Kang R.
        • Stern P.J.
        Fracture dislocations of the proximal interphalangeal joint.
        J Am Acad Orthop Surg. 2002; 2: 47-59
        • Kiefhaber T.R.
        • Stern P.J.
        Fracture dislocations of the proximal interphalangeal joint.
        J Hand Surg Am. 1998; 23: 368-380
        • Weiss L.E.
        • Sweet S.
        Operative treatment of volar PIP joint fracture dislocations.
        in: Julie E. PIP Joint Fracture Dislocations: A Clinical Casebook. Adams Springer International Publishing, 2016: 211-221
        • Rosenstadt B.E.
        • Glickel S.Z.
        • Lane L.B.
        • Kaplan S.J.
        Palmar fracture dislocation of the proximal interphalangeal joint.
        J Hand Surg. 1998; 23: 811-820
        • Weiss A.P.
        Cerclage fixation for fracture dislocation of the proximal interphalangeal joint.
        Clin Orthop Relat Res. 1996; 327: 21-28
        • Green A.
        • Smith J.
        • Redding M.
        • Akelman E.
        Acute openreduction and rigid internal fixation of proximal interphalangeal joint fracture dislocation.
        J Hand Surg. 1992; 17: 512-517
        • Grant I.
        • Berger A.C.
        • Tham S.K.
        Internal fixation of unstable fracture dislocations of the proximal interphalangeal joint.
        J Hand Surg. 2005; 30: 492-498
        • Meyer Z.I.
        • Goldfarb C.A.
        • Calfee R.P.
        • Wall L.B.
        The central slip fracture: results of operative treatment of volar fracture subluxations/dislocations of the proximal interphalangeal joint.
        J Hand Surg. 2017; 42: 572.e1-572.e6
        • Kang G.C.
        • Yam A.
        • Phoon E.S.
        • Lee J.Y.
        • Teoh L.C.
        The hook plate technique for fixation of phalangeal avulsion fractures.
        J Bone Joint Surg. 2012; 94: e72
        • Thirumalai A.
        • Mikalef P.
        • Jose R.M.
        The versatile hook plate in avulsion fractures of the hand.
        Ann of Plast Surg. 2017; 79: 270-274
        • Doering T.A.
        • Greenberg A.S.
        • Tuckman D.V.
        Dorsal plating for intra-articular middle phalangeal base fractures with volar instability.
        HAND. 2019; 14: 620-625