Sonographic Location of Distal A1 Pulley by Means of a Bony Acoustic Landmark on the Proximal Phalanx: An Anatomic Study

      Purpose

      To identify the anatomic relationship between the distal extent of the A1 pulley and the distalmost insertion point of the palmar plate into the base of the proximal phalanx at a metaphyseal bony ridge, the “P1 peak” (P1P), which is a bony acoustic landmark easily identifiable on sonography of the finger.

      Methods

      We studied 48 fingers (no thumbs) from 12 fresh frozen cadavers with high-resolution ultrasound. A 20-gauge hypodermic needle was directed perpendicular to the long axis of the tendon sheath along a plumb line drawn at the level of the bony flare of the proximal metaphyseal-diaphyseal junction of the proximal phalanx, or the P1P, under high-resolution ultrasound guidance. Dissection was then performed, and the distance of the needle barrel and the actual distance of the P1P from the distal edge of the A1 pulley were recorded.

      Results

      The study demonstrated that accurate placement of the needle within 1 mm of the actual P1P was possible using ultrasound guidance and that the P1P was within 1 mm of the distal edge of the actual A1 pulley in all specimens studied.

      Conclusions

      In all the specimens studied, we found that the P1P may be used as a clearly identifiable sonographic reference landmark to identify the distal extent of the A1 pulley.

      Clinical relevance

      Using the P1P landmark as a guide to judge the completeness of ultrasound-guided percutaneous trigger finger release may reduce the risks of incomplete distal release and inadvertent release of the A2 pulley.

      Key words

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Journal of Hand Surgery
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Ryzewicz M.
        • Wolf J.M.
        Trigger digits: principles, management, and complications.
        J Hand Surg Am. 2006; 31: 135-146
        • Zhao J.G.
        • Kan S.L.
        • Zhao L.
        • et al.
        Percutaneous first annular pulley release for trigger digits: a systematic review and meta-analysis of current evidence.
        J Hand Surg Am. 2014; 39: 2192-2202
        • Eastwood D.M.
        • Gupta K.J.
        • Johnson D.P.
        Percutaneous release of the trigger finger: an office procedure.
        J Hand Surg Am. 1992; 17: 114-117
        • Weiss N.D.
        • Richter M.B.
        Percutaneous release of trigger digits.
        Am J Orthop (Belle Mead NJ). 2017; 46: E263-E267
        • Jou I.M.
        • Chern T.C.
        Sonographically assisted percutaneous release of the A1 pulley: a new surgical technique for treating trigger digit.
        J Hand Surg Br. 2006; 31: 191-199
        • Kuo L.C.
        • Su F.C.
        • Tung W.L.
        • Lai K.Y.
        • Jou I.M.
        Kinematical and functional improvements of trigger digits after sonographically assisted percutaneous release of the A1 pulley.
        J Orthop Res. 2009; 27: 891-896
        • Rojo-Manaute J.M.
        • Rodríguez-Maruri G.
        • Capa-Grasa A.
        • Chana-Rodríguez F.
        • Soto Mdel V.
        • Martín J.V.
        Sonographically guided intrasheath percutaneous release of the first annular pulley for trigger digits, part 1: clinical efficacy and safety.
        J Ultrasound Med. 2012; 31: 417-424
        • Kim S.J.
        • Lee C.H.
        • Choi W.S.
        • Lee B.G.
        • Kim J.H.
        • Lee K.H.
        The thickness of the A2 pulley and the flexor tendon are related to the severity of trigger finger: results of a prospective study using high-resolution ultrasonography.
        J Hand Surg Eur Vol. 2016; 41: 204-211
        • Paulius K.L.
        • Maguina P.
        Ultrasound-assisted percutaneous trigger finger release: is it safe?.
        Hand (NY). 2009; 4: 35-37
        • Wilhelmi B.J.
        • Snyder N.
        • Verbesey J.E.
        • Ganchi P.A.
        • Lee W.P.A.
        Trigger finger release with hand surface landmark ratios: an anatomic and clinical study.
        Plast Reconstr Surg. 2001; 108: 908-915
        • Hazani R.
        • Engineer N.J.
        • Zeineh L.L.
        • Wilhelmi B.J.
        Assessment of the distal extent of the A1 pulley release: a new technique.
        Eplasty. 2008; 8: e44
        • Doyle J.R.
        Anatomy of the finger flexor tendon sheath and pulley system.
        J Hand Surg Am. 1988; 13: 473-484