Interosseous Membrane of the Forearm: An Anatomical Study of Ligament Attachment Locations

Published:February 12, 2009DOI:https://doi.org/10.1016/j.jhsa.2008.10.025

      Purpose

      The interosseous membrane (IOM) of the forearm is a stout ligamentous complex that reportedly comprises several ligamentous components. The purpose of this cadaveric study was to define all IOM ligaments and to clarify the precise attachment locations.

      Methods

      Thirty forearms from 15 embalmed cadavers were used. After dissection, all IOM ligaments were identified, and attachments were measured from the tip of the radial styloid or the ulnar head. Attachment locations were represented as a percentage of total bone length from the distal end of the radius or ulna.

      Results

      The IOM included 5 kinds of ligaments: central band, accessory band, distal oblique bundle, proximal oblique cord, and dorsal oblique accessory cord. The most distal and proximal ends of the radial origin of the central band were 53% and 64% of total radial length from the tip of the radial styloid, whereas those of the ulnar insertion were 29% and 44% of total ulnar length from the ulnar head. The center point of the radial origin and ulnar insertion of the accessory band were 37% and 23%, respectively. The center points of the ulnar origins and radial insertions were 15% and 10% for the distal oblique bundle; 80% and 79% for the proximal oblique cord; and 64% and 62% for the dorsal oblique accessory cord, respectively.

      Conclusions

      The present study clarified precise attachment locations of all representative IOM ligaments. This information will be useful in planning proper graft placement in ligament reconstruction surgery and for future biomechanics research into the function of the IOM ligaments.

      Key words

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Journal of Hand Surgery
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Hotchkiss R.N.
        • An K.-N.
        • Sowa D.T.
        • Basta S.
        • Weiland A.J.
        An anatomic and mechanical study of the interosseous membrane of the forearm: pathomechanics of proximal migration of the radius.
        J Hand Surg. 1989; 14A: 256-261
        • Skahen III, J.R.
        • Palmer A.K.
        • Werner F.W.
        • Fortino M.D.
        The interosseous membrane of the forearm: anatomy and function.
        J Hand Surg. 1997; 22A: 981-985
        • Poitevin L.A.
        Anatomy and biomechanics of the interosseous membrane: its importance in the longitudinal stability of the forearm.
        Hand Clin. 2001; 17: 97-110
        • Mori K.
        Experimental study on rotation of the forearm: functional anatomy of the interosseous membrane.
        J Jpn Orthop Assoc. 1985; 59: 611-622
        • Nakamura T.
        • Yabe Y.
        • Horiuchi Y.
        Functional anatomy of the interosseous membrane of the forearm: dynamic changes during rotation.
        Hand Surg. 1999; 4: 67-73
        • Fujita M.
        An anatomical study on the interosseous membrane of the forearm.
        J Jpn Orthop Assoc. 1995; 69: 938-950
        • Schneiderman G.
        • Meldrum R.D.
        • Bloebaum R.D.
        • Tarr R.
        • Sarmiento A.
        The interosseous membrane of the forearm: structure and its role in Galeazzi fractures.
        J Trauma. 1993; 35: 879-885
        • Skahen III, J.R.
        • Palmer A.K.
        • Werner F.W.
        • Fortino M.D.
        Reconstruction of the interosseous membrane of the forearm in cadavers.
        J Hand Surg. 1997; 22 (A.): 986-994
        • Rabinowitz R.S.
        • Light T.R.
        • Havey R.M.
        • Gourineni P.
        • Patwardhan A.G.
        • Sartori M.J.
        • et al.
        The role of the interosseous membrane and triangular fibrocartilage complex in forearm stability.
        J Hand Surg. 1994; 19 (A.): 385-393
        • Birkbeck D.P.
        • Failla J.M.
        • Hoshaw J.
        • Fyhrie D.P.
        • Schaffler M.
        The interosseous membrane affects load distribution in the forearm.
        J Hand Surg. 1997; 22A: 975-980
        • Pfaeffle H.J.
        • Stabile K.J.
        • Li Z.M.
        • Tomaino M.M.
        Reconstruction of the interosseous ligament restores normal forearm compressive load transfer in cadavers.
        J Hand Surg. 2005; 30A: 319-325
        • Kapandji A.
        Biomechanics of pronation and supination of the forearm.
        Hand Clin. 2001; 17: 111-122
        • Martin B.F.
        The oblique cord of the forearm.
        J Anat. 1958; 92: 609-615
        • Tubbs R.S.
        • O'Neil Jr, J.T.
        • Key C.D.
        • Zarzour J.G.
        • Fulghum S.B.
        • Kim E.J.
        • et al.
        Clin Anat. 2007; 20: 411-415
        • Patel B.A.
        Form and function of the oblique cord (chorda oblique) in anthropoid primates.
        Primates. 2005; 46: 47-57
        • Chandler J.W.
        • Stabile K.J.
        • Pfaeffle H.J.
        • Li Z.M.
        • Woo S.L.-Y.
        • Tomaino M.M.
        Anatomic parameters for planning of interosseous ligament reconstruction using computer-assisted techniques.
        J Hand Surg. 2003; 28A: 111-116
        • Hollister A.M.
        • Gellman H.
        • Waters R.L.
        The relationship of the interosseous membrane to the axis of rotation of the forearm.
        Clin Orthop Relat Res. 1994; 298: 272-276
        • Nakamura T.
        • Yabe Y.
        • Horiuchi Y.
        In vivo MR studies of dynamic changes in the interosseous membrane of the forearm during rotation.
        J Hand Surg. 1999; 24B: 245-248
        • Nakamura T.
        • Yabe Y.
        • Horiuchi Y.
        • Yamazaki N.
        Three-dimensional magnetic imaging of the interosseous membrane of forearm: a new method using fuzzy reasoning.
        Magn Reson Imaging. 1999; 17: 463-470
        • Nakamura T.
        • Yabe Y.
        • Horiuchi Y.
        • Seki T.
        • Yamazaki N.
        Normal kinematics of the interosseous membrane during forearm pronation-supination: a three-dimensional MRI study.
        Hand Surg. 2000; 5: 1-10
        • Watanabe H.
        • Berger R.A.
        • Berglund L.J.
        • Zobitz M.E.
        • An K.N.
        Contribution of the interosseous membrane to distal radioulnar joint constraint.
        J Hand Surg. 2005; 30A: 1164-1171
        • Kihara H.
        • Short W.H.
        • Werner F.W.
        • Fortino M.D.
        • Palmer A.K.
        The stabilizing mechanism of the distal radioulnar joint during pronation and supination.
        J Hand Surg. 1995; 20A: 930-936
        • Forster A.
        Uber den morphologischen Wert der Chorda oblique antebrachii anterior und der Chorda oblique antebrachii posterior.
        Z Morphol Anthropol. 1905; 8: 62-79