Original Communications| Volume 25, ISSUE 2, P270-276, March 2000

The A3 pulley

      Abstract

      The tendon-pulley geometry and gliding resistance with and without the A3 pulley were compared in 6 fresh human cadaver fingers. We measured the x-ray images of the distal A2 pulley-tendon angle and proximal A4 pulley-tendon angle with varying degrees of proximal interphalangeal joint flexion between 0° and 120° before and after A3 pulley resection. The gliding resistance of the flexor digitorum profundus tendon under the A2 pulley was also measured at varying tendon-pulley angles. With the A3 pulley removed, the tendon-pulley angle significantly increased compared with the A3 intact state. The gliding resistance between tendon and pulley quadratically increased as the tendon-pulley angle increase from 0° to 60°. These results indicate that the A3 pulley might serve to reduce tendon-pulley gliding resistance by reducing the tendon-pulley angle during finger flexion. (J Hand Surg 2000;25A:270–276. Copyright © 2000 by the American Society for Surgery of the Hand.)

      Keywords

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Journal of Hand Surgery
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Coert JH
        • Uchiyama S
        • Amadio PC
        • Berglund LJ
        • An K-N
        Flexor tendon-pulley interaction after tendon repair: a biomechanical study.
        J Hand Surg. 1995; 20B: 573-577
        • Karev A
        • Stahl S
        • Taran A.
        The mechanical efficiency of the pulley system in normal digits compared with a reconstructed system using the “belt loop” technique.
        J Hand Surg. 1987; 12A: 596-601
        • Phillips C
        • Mass D.
        Mechanical analysis of the palmar aponeurosis pulley in human cadavers.
        J Hand Surg. 1996; 21A: 240-244
        • Doyle JR.
        Anatomy of the flexor tendon sheath and pulley system: a current review.
        J Hand Surg. 1989; 14A: 349-351
        • Lin G-T
        • Amadio PC
        • An K-N
        • Cooney WP.
        Functional anatomy of the human digital flexor pulley system.
        J Hand Surg. 1989; 14A: 949-956
        • Seiler JG
        • Uchiyama S
        • Ellis F
        • Amadio PC
        • Gelberman RH
        • An K-N
        Reconstruction of the flexor pulley: the effect of the tension and source of the graft in an in vitro dog model.
        J Bone Joint Surg. 1998; 80A: 699-703
        • Uchiyama S
        • Coert JH
        • Berglund L
        • Amadio PC
        • An K-N.
        A method for measurement of friction between tendon and pulley.
        J Orthop Res. 1995; 13: 83-89
        • Barton NJ.
        Experimental study of optimal location of flexor tendon pulleys.
        Plast Reconstr Surg. 1969; 43: 125-129
        • Rispler D
        • Greenwald D
        • Shumway S
        • Allan C
        • Mass D.
        Efficiency of the flexor tendon pulley system in human cadaver hands.
        J Hand Surg. 1996; 21A: 444-450
        • Hamman J
        • Ali A
        • Phillips C
        • Cunningham B
        • Mass DP.
        A biomechanical study of the flexor digitorum superficialis: effects of digital pulley excision and loss of the flexor digitorum profundus.
        J Hand Surg. 1997; 22A: 328-335
        • An K-N
        • Berglund L
        • Uchiyama S
        • Coert JH.
        Measurement of friction between pulley and flexor tendon.
        Biomed Sci Instrum. 1993; 29: 1-7
        • Amadio PC
        • Lin GT
        • An K-N.
        Anatomy and pathomechanics of the flexor pulley system.
        J Hand Ther. 1987; 2: 138-141
        • Doyle JR.
        Anatomy of the finger flexor tendon sheath and pulley system.
        J Hand Surg. 1988; 13A: 473-484
        • Zhao C
        • Amadio PC
        • An K-N
        • Zobitz ME
        Gliding characteristics of tendon repair in partially lacerated canine flexor digitorum profundus tendons.
        Orthop Trans. 1999; 23 (abstr): 120
        • Peck FH
        • Bücher CA
        • Watson JS
        • Roe A.
        A comparative study of two methods of controlled mobilization of flexor tendon repairs in zone 2.
        J Hand Surg. 1998; 23B: 41-45
        • Tang JB.
        Flexor tendon repair in zone 2C.
        J Hand Surg. 1994; 19B: 72-75
        • Williams RJN
        • Amis AA.
        A new type of flexor tendon repair: biomechanical evaluation by cyclic loading, ultimate strength and assessment of pulley friction in vitro.
        J Hand Surg. 1995; 20B: 578-583
        • Aoki M
        • Manske PR
        • Pruitt DL
        • Larson BJ.
        Work of flexion after tendon repair with various suture methods: a human cadaveric study.
        J Hand Surg. 1995; 20B: 310-313
        • Amis AA
        • Jones MM.
        The interior of the flexor tendon sheath of the finger: the functional significance of its structure.
        J Bone Joint Surg. 1988; 70B: 583-587
        • Moro-oka T
        • Miura H
        • Higaki H
        • Mawatari T
        • Murakami T
        • Iwamoto Y
        The boundary lubricating ability of phospholipid on flexor tendon of rabbit.
        Orthop Trans. 1999; 23 (abstr): 316
        • Peterson WW
        • Manske PR
        • Bollinger BA
        • Lesker PA
        • McCarthy JA.
        Effect of pulley excision on flexor tendon biomechanics.
        J Orthop Res. 1986; 4: 96-101
        • Lin G-T
        • Amadio PC
        • An K-N
        • Cooney WP
        • Chao EYS.
        Biomechanical analysis of finger flexor pulley reconstruction.
        J Hand Surg. 1989; 14B: 278-282