« Previous
Next »
Journal of Hand Surgery
Volume 35, Issue 4
, Pages 597-603
, April 2010
Comparison Between Locking and Non-Locking Plates for Fixation of Metacarpal Fractures in an Animal Model
References
- . Operative treatment of common displaced and unstable fractures of the hand. Instr Course Lect. 2002;51:185–201
- . Extraarticular hand fractures in adults: a review of new developments. Clin Orthop Relat Res. 2006;445:133–145
- . Operative treatment of metacarpal and phalangeal shaft fractures. J Am Acad Orthop Surg. 2000;8:111–121
- . Management of fractures of the hand over the last 25 years. J Hand Surg. 2000;25A:817–823
- . Locked intramedullary nailing of metacarpal fractures secondary to gunshot wounds. J Hand Surg. 2006;31A:1083–1087
- . Intramedullary nailing of metacarpal shaft fractures. Tech Hand Up Extrem Surg. 2005;9:69–73
- . Open hand fractures: an analysis of the recovery of active motion and complications. J Hand Surg. 1993;18A:387–394
- Biomechanical study of four palmar locking plates and one non-locking palmar plate for distal radius fractures: stiffness and load to failure tests in a cadaver model [in German]. Biomed Tech. 2009;54:150–158
- Locked vs. unlocked plate osteosynthesis of the proximal humerus—a biomechanical study. Clin Biomech. 2007;22:176–182Epub 2006 Nov 28
- . Biomechanical comparison of a unique locking plate versus a standard plate for internal fixation of proximal humerus fractures in a cadaveric model. Clin Biomech. 2006;21:1027–1031Epub 2006 Aug 17
- . Biomechanical analysis of distal femur fracture fixation: fixed-angle screw-plate construct versus condylar blade plate. J Orthop Trauma. 2007;21:43–46
- Experiences in the treatment of midfascial fractures using a fixed-angle osteosynthetic system (Biomechanical results [in German]). Mund Kiefer Gesichtschir. 2004;8:154–162
- . A phalangeal fracture model—quantitative analysis of rigidity and failure. J Hand Surg. 1982;7:264–270
- Bioabsorbable miniplating versus metallic fixation for metacarpal fractures. Clin Orthop Relat Res. 2003;410:310–319
- . Self-reinforced bioabsorbable versus metallic fixation systems for metacarpal and phalangeal fractures: a biomechanical study. J Hand Surg. 2002;27A:902–909
- . Mechanical analysis of Kirschner wire fixation in a phalangeal model. J Hand Surg. 1979;4:351–356
- . Basic biomechanical measurements of bone: a tutorial. Bone. 1993;14:595–608
- . Spiral fracture fixation techniques (A biomechanical study). J Hand Surg. 1993;18B:515–519
- . In vitro comparison of lagged and nonlagged screw fixation of metacarpal fractures in cadavers. J Hand Surg. 2008;33A:1732–1736
- . Comparison of internal fixation techniques in metacarpal fractures. J Hand Surg. 1985;10A:466–472
- Mini and micro plating of phalangeal and metacarpal fractures: a biomechanical study. J Hand Surg. 1995;20A:44–49
- . Comparative fatigue strengths and stabilities of metacarpal internal fixation techniques. J Hand Surg. 1993;18:1059–1068
- . Biomechanical and functional testing of plate fixation devices for proximal phalangeal fractures. J Hand Surg. 1991;16A:991–998
- . A quantitative comparison of metacarpal fracture stability with five different methods of internal fixation. J Hand Surg. 1985;10A:1024–1028
- . Low-profile versus conventional metacarpal plating systems: a comparison of construct stiffness and strength. J Hand Surg. 1999;24A:928–934
- . Fixation of hand fractures with bicortical screws. J Hand Surg. 2005;30A:151–153
- . Comparison of intramedullary nailing versus plate-screw fixation of extra-articular metacarpal fractures. J Hand Surg. 2008;33A:1724–1731
- . Plating of metacarpal fractures: unicortical or bicortical screws?. J Hand Surg. 2004;29B:216–219
- . Comparison of metacarpal plating methods. J Hand Surg. 2008;33A:316–321
- . Complications of plate fixation in metacarpal fractures. J Trauma. 2002;52:535–539
- . Complications and range of motion following plate following plate fixation of metacarpal and phalangeal fractures. J Hand Surg. 1998;23A:827–832
- . Monocortical versus bicortical plate fixation in a metacarpal fracture model. Unfallchirurg. 2005;108(electronic Suppl):630
- . Force transfer between the plate and the bone: relative importance of the bending stiffness of the screws friction between plate and bone. Injury. 2000;31(Suppl 3):C21–C28
- . Biomechanics of locked plates and screws. J Orthop Trauma. 2004;18:488–493
- . Mechanical characteristics of locking and compression plate constructs applied dorsally to distal radius fractures. J Hand Surg. 2007;32A:623–629
- . Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg. 2002;27A:205–215
Support was provided by Stryker Corporation, Freiburg, Germany, for implant and material costs. No benefits in any form have been received or will be received related directly or indirectly to the subject of this article.
PII: S0363-5023(10)00003-1
doi: 10.1016/j.jhsa.2010.01.002
© 2010 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Journal of Hand Surgery
Volume 35, Issue 4
, Pages 597-603
, April 2010

