Journal of Hand Surgery
Volume 35, Issue 4 , Pages 639-644 , April 2010

Biomechanical Comparison of Contemporary Clavicle Fixation Devices

  • Timothy Renfree, MD
  • ,
  • Bryan Conrad, PhD
  • ,
  • Thomas Wright, MD

      Affiliations

    • Corresponding Author InformationCorresponding author: Thomas Wright, MD, Department of Orthopaedics and Rehabilitation, University of Florida, 3450 Hull Road, Gainesville, FL 32607

Received 10 August 2009 ,Accepted 7 December 2009.

References 

  1. Canadian Orthopaedic Trauma Society. Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures (A multi-center, randomized clinical trial). J Bone Joint Surg. 2007;89A:1–10
  2. Zlowodzki M, Zelle BA, Cole PA, Jeray K, McKee MD. Treatment of acute midshaft clavicle fractures: systematic review of 2144 fractures: on behalf of the Evidence-Based Orthopaedic Trauma Working Group. J Orthop Trauma. 2005;19:504–507
  3. Abbott LC, Lucas DB. The function of the clavicle: its surgical significance. Ann Surg. 1954;140:583–599
  4. Ring D, Holovacs T. Brachial plexus palsy after intramedullary fixation of a clavicular fracture (A report of three cases). J Bone Joint Surg. 2005;87A:1834–1837
  5. Hill JM, McGuire MH, Crosby LA. Closed treatment of displaced middle-third fractures of the clavicle gives poor results. J Bone Joint Surg. 1997;79B:537–539
  6. Nordqvist A, Petersson CJ, Redlund-Johnell I. Mid-clavicle fractures in adults: end result study after conservative treatment. J Orthop Trauma. 1998;12:572–576
  7. Nowak J, Holgersson M, Larsson S. Can we predict long-term sequelae after fractures of the clavicle based on initial findings? (A prospective study with nine to ten years of follow-up). J Shoulder Elbow Surg. 2004;13:479–486
  8. Oroko PK, Buchan M, Winkler A, Kelly IG. Does shortening matter after clavicular fractures?. Bull Hosp Jt Dis. 1999;58:6–8
  9. Robinson CM, Court-Brown CM, McQueen MM, Wakefield AE. Estimating the risk of nonunion following nonoperative treatment of a clavicular fracture. J Bone Joint Surg. 2004;86A:1359–1365
  10. Shen WJ, Liu TJ, Shen YS. Plate fixation of fresh displaced midshaft clavicle fractures. Injury. 1999;30:497–500
  11. Simpson NS, Jupiter JB. Clavicular nonunion and malunion: evaluation and surgical management. J Am Acad Orthop Surg. 1996;4:1–8
  12. Wick M, Műller EJ, Kollig E, Muhr G. Midshaft fractures of the clavicle with a shortening of more than 2 cm predispose to nonunion. Arch Orthop Trauma Surg. 2001;121:207–211
  13. McKee MD, Pedersen EM, Jones C, Stephen DJ, Kreder HJ, Schemitsch EH, et al. Deficits following nonoperative treatment of displaced midshaft clavicular fractures. J Bone Joint Surg. 2006;88A:35–40
  14. Kemper A, Stitzel J, Gabler C, Duma S, Matsuoka F. Biomechanical response of the human clavicle subjected to dynamic bending. Biomed Sci Instrum. 2006;42:231–236
  15. Gardner MJ, Griffith MH, Demetrakopoulos D, Brophy RH, Grose A, Helfet DL, et al. Hybrid locked plating of osteoporotic fractures of the humerus. J Bone Joint Surg. 2006;88A:1962–1967
  16. Rubel IF, Kloen P, Campbell D, Schwartz M, Liew A, Myers E, et al. Open reduction and internal fixation of humeral nonunions: a biomechanical and clinical study. J Bone Joint Surg. 2002;84A:1315–1322
  17. Nordqvist A, Petersson C. The incidence of fractures of the clavicle. Clin Orthop Relat Res. 1994;300:127–132
  18. Celestre P, Robertson C, Mahar A, Oka R, Meunier M, Schwartz A. Biomechanical evaluation of clavicle fracture plating techniques: does a locking plate provide improved stability?. J Orthop Trauma. 2008;22:241–247
  19. Robertson C, Celestre P, Mahar A, Schwartz A. Reconstruction plates for stabilization of mid-shaft clavicle fractures: differences between nonlocked and locked plates in two different positions. J Shoulder Elbow Surg. 2009;18:204–209
  20. Proubasta IR, Itarte JP, Cáceres EP, Llusá MP, Gil MJ, Planell JA, et al. Biomechanical evaluation of fixation of clavicular fractures. J South Orthop Assoc. 2002;11:148–152
  21. Harnroongroj T, Tantikul C, Keatkor S. The clavicular fracture: a biomechanical study of the mechanism of clavicular fracture and modes of the fracture. J Med Assoc Thai. 2000;83:663–667
  22. Harnroongroj T, Vanadurongwan V. Biomechanical aspects of plating osteosynthesis of transverse clavicular fracture with and without inferior cortical defect. Clin Biomech (Bristol, Avon). 1996;11:290–294
  23. Iannotti MR, Crosby LA, Stafford P, Grayson G, Goulet R. Effects of plate location and selection on the stability of midshaft clavicle osteotomies: a biomechanical study. J Shoulder Elbow Surg. 2002;11:457–462
  24. Graves ML, Geissler WB, Freeland AE. Midshaft clavicular fractures: the role of operative treatment. Orthopedics. 2005;28:761–764

 The plates tested in this study were donated by Acumed (Hillsboro, OR), and the pins were donated by DePuy (Warsaw, IN). Joanne Clarke assisted with the revision and completion of the manuscript. No benefits in any form have been received or will be received related directly or indirectly to the subject of this article.

PII: S0363-5023(09)01113-7

doi: 10.1016/j.jhsa.2009.12.012

Journal of Hand Surgery
Volume 35, Issue 4 , Pages 639-644 , April 2010